• DocumentCode
    906757
  • Title

    A Microwave Decoupled Brain-Temperature Transducer

  • Author

    Larsen, Lawrence E. ; Moore, Robert Avery ; Acevedo, John

  • Volume
    22
  • Issue
    4
  • fYear
    1974
  • fDate
    4/1/1974 12:00:00 AM
  • Firstpage
    438
  • Lastpage
    444
  • Abstract
    Bench test studies of conventional temperature transducers in microwave environments have demonstrated artifacts responsible for errors of several degrees centigrade. These findings led to a program for the development of systematic test procedures and the design of electrodes with artifact reduced to 0.1°C.
  • Keywords
    Dielectric losses; Electromagnetic heating; Electromagnetic wave absorption; Laboratories; Microwave measurements; Probes; Temperature distribution; Temperature measurement; Temperature sensors; Transducers;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1974.1128244
  • Filename
    1128244