DocumentCode
906943
Title
Triangular Spect System for 3-D Total Organ Volume Imaging: Design Concept and Preliminary Imaging Results
Author
Lim, C.B. ; Gottschalk, S. ; Walker, R. ; Schreiner, R. ; Valentino, F. ; Pinkstaff, C. ; Janzo, J. ; Covic, J. ; Perusek, A. ; Anderson, J. ; Kim, K.I. ; Shand, D. ; Coulman, K. ; King, S. ; Styblo, D.
Author_Institution
Technicare Corporation, 29100 Aurora Road, Solon, Ohio 44139
Volume
32
Issue
1
fYear
1985
Firstpage
741
Lastpage
747
Abstract
SPECT systems based on 2-D detectors for projection data collection and filtered back-projection image reconstruction have the potential for true 3-D imaging, providing contiguous slice images in any orientation. Anger camera-based SPECT systems have the natural advantage supporting planar imaging clinical procedures. However, current systems suffer from two drawbacks; poor utilization of emitted photons, and inadequate system design for SPECT. A SPECT system consisting of three rectangular cameras with radial translation would offer the variable cylindrical FOV of 25 cm to 40 cm diameter allowing close detector access to the object. This system would provide optimized imaging for both brain and body organs in terms of sensitivity and resolution. For brain imaging a tight detector triangle with fan beam collimation, matching detector UFOV to the head, allows full 2¿ utilization of emitted photons, resulting in >4 times sensitivity increase over the single detector system. Minification of intrinsic detector resolution in fan beam collimation further improves system resolution. For body organ imaging the three detectors with parallel hole collimators, rotating in non-circular orbit, provide both improved resolution and three-fold sensitivity increase. Practical challenges lie in ensuring perfect image overlap from three detectors without resolution degradation and artifact generation in order to benefit from the above improvements. An experimental system has been developed to test the above imaging concept and we have successfully demonstrated the superior image quality of the overlapped images. Design concept will be presented with preliminary imaging results.
Keywords
Brain; Cameras; Degradation; Detectors; Head; Image reconstruction; Image resolution; Object detection; Optical collimators; Single photon emission computed tomography;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1985.4336934
Filename
4336934
Link To Document