DocumentCode :
906969
Title :
Application of Simulated Annealing to Coded-Aperture Design and Tomographic Reconstruction
Author :
Smith, W.E. ; Paxman, R.G. ; Barrett, H.H.
Author_Institution :
Optical Sciences Center University of Arizona Tucson, AZ 85721
Volume :
32
Issue :
1
fYear :
1985
Firstpage :
758
Lastpage :
761
Abstract :
Reconstructions from coded-image data obtained with the simulated annealing algorithm are presented along with an experiment testing the effects of annealing. An efficient perturbation method for system optimization is defined, and the role of simulated annealing in such an optimization is discussed.
Keywords :
Apertures; Cost function; Gamma ray detection; Gamma ray detectors; Image reconstruction; Optical imaging; Optimization methods; Perturbation methods; Simulated annealing; Tomography;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1985.4336937
Filename :
4336937