Title :
Position detection of 17-25 kev x-rays in krypton and xenon with a resolution of 18-50μm (FWHM)
Author :
Fischer, J. ; Radeka, V. ; Smith, G.C.
Author_Institution :
Brookhaven National Laboratory Upton, New York 11973-5000
Abstract :
Measurements have been made of x-ray position resolution in a proportional chamber with both Kr/10% CO2/sub> and Xe/10% CO2/sub>, for the x-ray energy region 17-25 keV. Position resolutions in the range of 18-50μm (FWHM) are obtained in krypton, and in the range 50-100 μm (FWHM) for xenon. These results are interpreted in terms of the physical limitation to resolution due to the range of photoelectrons and Auger electrons emitted from the x-ray absorbing atom.
Keywords :
Anodes; Electromagnetic wave absorption; Electron emission; Energy measurement; Energy resolution; Fluorescence; Position measurement; X-ray detection; X-ray detectors; Xenon;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1986.4337095