• DocumentCode
    908804
  • Title

    Measurement of Atmospheric Attenuation at 1.3 and 0.87 mm with an Harmonic Mixing Radiometer

  • Author

    Goldsmith, Paul F. ; Plambeck, Richard L. ; Chiao, Raymond Y.

  • Volume
    22
  • Issue
    12
  • fYear
    1974
  • fDate
    12/1/1974 12:00:00 AM
  • Firstpage
    1115
  • Lastpage
    1116
  • Abstract
    The atmospheric attenuation at 1.3 and 0.87 mm was measured above Mount Hamilton, California in the period December 5 to December 9, 1973. The measured value of the zenith attenuation varied from 1 to 5 dB at 1.3 mm over this five-day period, and was 2.5 dB at 0.87 mm on December 9, 1973. The total beamwidth of the 120" Lick Observatory telescope used in the Coude configuration was measured to be 3\´ at 1.3 mm.
  • Keywords
    Atmosphere; Atmospheric measurements; Attenuation measurement; Local oscillators; Microwave radiometry; Optical attenuators; Optical receivers; Telescopes; Temperature measurement; Venus;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1974.1128444
  • Filename
    1128444