• DocumentCode
    909102
  • Title

    A Microwave Dosimetry System for Measured Sampled Integral-Dose Rate

  • Author

    Christman, Christopher L. ; Ho, Henry S. ; Yarrow, Sheppard

  • Volume
    22
  • Issue
    12
  • fYear
    1974
  • fDate
    12/1/1974 12:00:00 AM
  • Firstpage
    1267
  • Lastpage
    1272
  • Abstract
    An interface has been developed to allow the measurement of sampled integral-dose rate, defined as the change in integral dose during a particular time interval divided by that interval, absorbed by test animals as they are exposed in a waveguide to 2450-MHz CW microwave energy. The purpose of this investigation is to quantify the variations in sampled integral-dose rate as a result of the animal movements and to compare different irradiation procedures with respect to variations in sampled integral-dose rate.
  • Keywords
    Animals; Dosimetry; Electromagnetic measurements; Electromagnetic wave absorption; Electromagnetic waveguides; Magnetic field measurement; Microwave measurements; Testing; Time measurement; Voltage;
  • fLanguage
    English
  • Journal_Title
    Microwave Theory and Techniques, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9480
  • Type

    jour

  • DOI
    10.1109/TMTT.1974.1128474
  • Filename
    1128474