• DocumentCode
    909297
  • Title

    An Evaluation of the Use of Sieves for Producing Estimates. Of Radioactivity Distributions with the EM Algorithm for PET

  • Author

    Miller, Michael I. ; Snyder, Donald L. ; Moore, Stephen M.

  • Author_Institution
    Department of Electrical Engineering and Institute for Biomedical Computing Washington University St. Louis, Missouri 63130
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    492
  • Lastpage
    495
  • Abstract
    Reconstructions of spatial-distributions of radioactivity produced using maximum-likelihood estimation in positron-emission tomography exhibit noise-like artifacts in the form of sharp peaks and valleys located randomly throughout the image field. These become increasingly apparent with each stage of iteration when the expectation-maximization algorithm is used to produce the maximum-likelihood estimate numerically. In this paper, we present a preliminary evaluation of the use of Grenander´s method of sieves to reduce these undesirable artifacts.
  • Keywords
    Biomedical computing; Expectation-maximization algorithms; Image reconstruction; Laboratories; Maximum likelihood detection; Maximum likelihood estimation; Positron emission tomography; Signal resolution; Signal to noise ratio; Single photon emission computed tomography;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337150
  • Filename
    4337150