Title :
How to Determine the 2T Pulse K Factor of TV Facilities Without the Aid of an Oscilloscope Graticule
Author_Institution :
American Broadcasting Company
fDate :
3/1/1969 12:00:00 AM
Abstract :
The K factor of a 2T pulse waveform is usually determined by fitting the waveform into an oscilloscope mask at prescribed deflection factors. Quite often a mask is not available, or a picture of the waveform is given with amplitude and time coordinates only. For these cases a method is presented which permits the K factor to be determined algebraically.
Keywords :
Area measurement; Distortion measurement; Helium; Oscilloscopes; Pulse generation; Pulse measurements; Pulse shaping methods; Shape measurement; System testing; TV;
Journal_Title :
Broadcasting, IEEE Transactions on
DOI :
10.1109/TBC.1969.265970