Title :
Design and Performance of a CCD Based Readout for the Delphi Barrel Electromagnetic Calorimeter
Author :
Crawley, H.B. ; Holland, G.E. ; Homer, J.F., Jr. ; McKay, R. ; Meyer, W.T. ; Rosenberg, E.I. ; Thomas, W.D.
Author_Institution :
Department of Physics and Ames Laboratory, USDOE Iowa State University, Ames, Iowa 50011
Abstract :
We describe the design criteria and performance of a CCD based readout system developed for use in the DELPHI experiment at LEP. These circuits are designed for use on the cathode pads of the High Density Projection Chamber (HPC) which will serve as the DELPHI central region electromagnetic calorimeter. Two separate CAMAC versions of this system have been tested on prototype HPC modules exposed to both hadrons and electrons. Stability and performance characteristics of these circuits at CCD input frequencies up to 20 MHz are presented. We also present results on the electron shower energy resolution for the HPC prototypes.
Keywords :
CAMAC; Cathodes; Charge coupled devices; Circuit stability; Circuit testing; Electrons; Energy resolution; Frequency; Prototypes; System testing;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1986.4337242