• DocumentCode
    910340
  • Title

    MARK II End Cap Calorimeter Electronics

  • Author

    Jared, R.C. ; Haggerty, J.S. ; Herrup, D.A. ; Kirsten, F.A. ; Lee, K.L. ; Olson, S.R. ; Wood, D.R.

  • Author_Institution
    Lawrence Berkeley Laboratory Berkeley, CA 94720 U.S.A.
  • Volume
    33
  • Issue
    1
  • fYear
    1986
  • Firstpage
    916
  • Lastpage
    921
  • Abstract
    An end cap calorimeter system has been added to the MARK II detector in preparation for its use at the SLAC Linear Collider. The calorimeter uses 8744 rectangular proportional counter tubes. This paper describes the design features of the data acquisition electronics that has been installed on the calorimeter. The design and use of computer-based test stands for the amplification and signal-shaping components is also covered. A portion of the complete system has been tested in a beam at SLAC. In these initial tests, using only the calibration provided by the test stands, a resolution of 18%/¿E* was achieved.
  • Keywords
    Calibration; Circuit testing; Coaxial cables; Detectors; Electron tubes; Preamplifiers; Pulse amplifiers; Signal design; Signal resolution; System testing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1986.4337248
  • Filename
    4337248