DocumentCode :
910379
Title :
Rotor winding short detection
Author :
Wood, J.W. ; Hindmarch, R.T.
Author_Institution :
NEI Parsons Ltd., Research and Development Laboratories, Newcastle upon Tyne, UK
Volume :
133
Issue :
3
fYear :
1986
fDate :
5/1/1986 12:00:00 AM
Firstpage :
181
Lastpage :
189
Abstract :
The paper presents a review of four techniques which are used for detecting, and in some instances locating, short-circuited turns in the rotors of large turbogenerators. The information is supplemented by experience with some of the techniques gained in a manufacturing establishment. The four techniques described are airgap search coil, recurrent surge oscillograph (RSO), circulating stator current, and rotor shaft current.
Keywords :
electric current measurement; fault location; machine testing; rotors; short-circuit currents; turbogenerators; airgap search coil; circulating stator current; recurrent surge oscillograph; rotor shaft current; rotor windings; short circuit detection; turbogenerators;
fLanguage :
English
Journal_Title :
Electric Power Applications, IEE Proceedings B
Publisher :
iet
ISSN :
0143-7038
Type :
jour
DOI :
10.1049/ip-b:19860025