• DocumentCode
    910404
  • Title

    Electrical machine core imperfection detection

  • Author

    Rickson, C.

  • Author_Institution
    Adwel Industries Ltd., Ruislip, UK
  • Volume
    133
  • Issue
    3
  • fYear
    1986
  • fDate
    5/1/1986 12:00:00 AM
  • Firstpage
    190
  • Lastpage
    195
  • Abstract
    The paper describes the development of a core imperfection monitoring and detection system which eliminates the need for a high-voltage high-current excitation winding. The system is based on an electromagnetic testing technique. The paper reports a number of tests conducted in the United Kingdom and USA and gives comparisons of results made with the conventional ring flux test method and the new method. Accuracy of fault location and ease of implementation are discussed.
  • Keywords
    electric machines; fault location; machine testing; monitoring; stators; core imperfection monitoring; electromagnetic testing; fault location; generators; motors; ring flux test; stator cores;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IEE Proceedings B
  • Publisher
    iet
  • ISSN
    0143-7038
  • Type

    jour

  • DOI
    10.1049/ip-b:19860026
  • Filename
    4644167