DocumentCode
911876
Title
Results of silicon strip detector readout using a CMOS low power microplex (MX1)
Author
Seller, P. ; Allport, P.P. ; Tyndel, M.
Author_Institution
Rutherford Appleton Lab., Chilton, UK
Volume
35
Issue
1
fYear
1988
Firstpage
176
Lastpage
180
Abstract
A system for reading out silicon strip detectors has been fabricated on a CMOS integrated circuit. The chip consists of an array of 128 amplifiers with a single multiplexed output. These chips have been bonded to a 256-channel silicon strip detector. Results are reported on the electrical parameters of the chips and on data taken during exposure of the instrumented detectors to minimum-ionizing beta particles. The radiation tolerance of the device has been investigated. The MX1 is working to specification and is presently being incorporated into equipment.<>
Keywords
electron detection and measurement; semiconductor counters; CMOS low power microplex; Si strip detector; electrical parameters; instrumented detectors; minimum-ionizing beta particles; single multiplexed output; Bonding; CMOS integrated circuits; Capacitors; Circuit noise; Clocks; Detectors; Laboratories; Silicon; Strips; Switches;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/23.12700
Filename
12700
Link To Document