DocumentCode
911878
Title
The CDF Forward/Backward Hadron Calorimeter
Author
Buchholz, J. ; Cihangir, S. ; Marchetto, F. ; Meyer, T. ; Webb, R.
Author_Institution
Physics Department Texas A&M University College Station, Texas 77843
Volume
34
Issue
1
fYear
1987
Firstpage
511
Lastpage
515
Abstract
We have constructed and tested a hadron calorimeter composed of proportional tube chambers and steel plates designed for the forward/backward spectrometer of the Collider Detector at Fermilab (CDF). The readout of this calorimeter is accomplished through sensing the induced charge pulses produced on the chamber´s cathode in response to a hadronic cascade shower. We describe the main features of these chambers and present the results of a performance tests for the first group of chambers produced.
Keywords
Assembly; Azimuth; Cathodes; Circuits; Ionization chambers; Physics; Poles and towers; Spectroscopy; Steel; Wires;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1987.4337395
Filename
4337395
Link To Document