DocumentCode :
912735
Title :
Comments on "High-resolution frequency-wavenumber spectrum analysis"
Author :
Seligson, C.D.
Volume :
58
Issue :
6
fYear :
1970
fDate :
6/1/1970 12:00:00 AM
Firstpage :
947
Lastpage :
949
Abstract :
Capon has described an estimator that can be used to discriminate between wavefronts incident upon an array of sensors from different directions. It is shown here that for a received field consisting of a single "signal" wavefront and an uncorrelated "noise" component, Capon\´s estimator displays less angular resolution than the conventional estimator when the amplitudes and the delays of the received wavefront are not known within a given tolerance.
Keywords :
Capacitance; Chemical technology; Counting circuits; Frequency estimation; Semiconductor diodes; Sensor arrays; Signal analysis; Stability; Switching circuits; Transient analysis;
fLanguage :
English
Journal_Title :
Proceedings of the IEEE
Publisher :
ieee
ISSN :
0018-9219
Type :
jour
DOI :
10.1109/PROC.1970.7825
Filename :
1449755