DocumentCode
913357
Title
Additional Information on the Noise-Temperature Behavior of F8T5 Lamps (Letters)
Author
Guentzler, Ronald E.
Volume
24
Issue
8
fYear
1976
fDate
8/1/1976 12:00:00 AM
Firstpage
538
Lastpage
539
Abstract
Noise temperature versus bulb temperature is given for an F8T5 lamp operating at 160-mA dc at bulb temperatures from 0 to 70°C. The new values supplement and correct previously published values. The behavior of the noise temperature is explained in terms of an Ar discharge at low bulb temperatures and the normal Hg-Ar discharge at high temperatures.
Keywords
Containers; Directional couplers; Electromagnetic wave absorption; Frequency; Impedance; Lamps; Measurement errors; Power measurement; Solids; Stripline;