    An RCL sensor for measuring dielectrically lossy materials in the MHz frequency range. Part I. Comparison of hydrogel model simulation with actual hydrogel impedance measurements

  • Author

    Talary, M.S. ; Dewarrat, F. ; Caduff, A. ; Puzenko, A. ; Ryabov, Y. ; Feldman, Y.

  • Author_Institution
    Solianis Monitoring AG, Zurich, Switzerland
  • Volume
    13
  • Issue
    2
  • fYear
    2006
  • fDate
    4/1/2006 12:00:00 AM
  • Firstpage
    247
  • Lastpage
    256
  • Abstract
    There is a requirement for the development of non-invasive continuous blood glucose monitoring devices to meet the clinical demands of the rapidly increasing number of people currently developing diabetes mellitus. Impedance spectroscopy is a technology that meets the requirements of such devices. An NI CGMD is being developed as a device that couples a sensor to the skin to form an RCL sensor. The reliability of such an RCL sensor model has been investigated by comparing electrodynamical simulations to in-vitro measurements of dielectrically "lossy" materials. The sensor has been modeled and simulated in FEMLAB (finite element modeling laboratory). In-vitro measurements are performed on hydrogels, representing the lossy material, by the aid of a Rohde & Schwarz VNA (vector network analyzer). From the quantitative agreement of the results we conclude, that the proposed qualitative model is appropriate for the characterization of the RCL sensor and suggests that more detailed models can be used to elucidate the behavior of human skin tissue.
  • Keywords
    bioelectric phenomena; biomedical equipment; biomedical measurement; blood; circuit simulation; dielectric loss measurement; diseases; electric impedance measurement; electric sensing devices; equivalent circuits; finite element analysis; gels; network analysers; patient diagnosis; patient monitoring; reliability; skin; FEMLAB; NICGMD; RCL sensor; Rohde-Schwarz VNA; blood glucose monitoring device; circuit simulation; diabetes mellitus; dielectrically lossy material; electrodynamical simulation; equivalent circuit; human skin tissue; hydrogel model simulation; impedance measurement; impedance spectroscopy; in-vitro measurement; medical diagnosis; noninvasive device; reliability; transducer; vector network analyzer; Blood; Dielectric loss measurement; Dielectric losses; Dielectric materials; Dielectric measurements; Frequency measurement; Impedance measurement; In vitro; Loss measurement; Skin;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2006.1624269
  • Filename
    1624269