Title :
The Measurement of the Equivalent Admittance of 3-Port Circulators Via an Automated Measurement System (Short Papers)
Author :
Riblet, Gordon P.
fDate :
5/1/1977 12:00:00 AM
Abstract :
A derivation of the equivalent admittance of symmetrical 3-port circulators is given which is based on the requirement that the S-matrix eigenvalues be separated by 120° on the unit circle for perfect circulation. This quantity has the property that if a 2-port matching network is found which matches into this admittance, then the same matching network connected in each circulator arm will match the circulator. It was used in conjunction with a computerized measurement system to determine the optimal single-step transformer matching of a stripline 3.7-4.2-GHz circulator and resulted in a device with performance better than 30 dB over this band.
Keywords :
Admittance measurement; Amplitude modulation; Anodes; Circulators; Contacts; Extraterrestrial measurements; Flanges; Klystrons; Schottky diodes; Temperature;
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
DOI :