DocumentCode
915602
Title
High voltage control and monitoring system for proportional chambers
Author
Saarloos, J. ; Olson, S. ; Carithers, W. ; Haber, C. ; Orme, C. ; Siegrist, J.
Author_Institution
Lawrence Berkeley Lab., California Univ., Berkeley, CA, USA
Volume
35
Issue
1
fYear
1988
Firstpage
191
Lastpage
192
Abstract
A description is given of a system that has been built and operated for distributing high voltage to 2000 channels of proportional chambers in the gas calorimeters of the CDF detector. The system consists of CAMAC-based controllers and distribution modules in the Rabbit hardware standard developed at Fermilab. Current monitoring to 1 nA and remote disconnect are available on each channel.<>
Keywords
proportional counters; CAMAC-based controllers; CDF detector; Fermilab; Rabbit hardware standard; distribution modules; gas calorimeters; monitoring system; proportional chambers; CAMAC; Circuits; Detectors; Dynamic range; Hardware; Rabbits; Relays; Remote monitoring; Standards development; Voltage control;