Title :
Wear-out failure mechanism in fused-fibre couplers
Author_Institution :
BT Group Tech. Facilities, Birmingham, UK
fDate :
6/10/1993 12:00:00 AM
Abstract :
A wear-out failure mechanism found in singlemode fused-fibre couplers is proposed and evidence presented. Exposure to humidity causes a swelling of the epoxy supporting the taper which in turn applies strain. Defects on the surface of the taper grow under the combined effects of humidity and strain and can, eventually, cause a fracture.
Keywords :
environmental degradation; failure analysis; fracture; optical couplers; optical fibre testing; swelling; fracture; fused-fibre couplers; humidity exposure; swelling; taper surface defects; wear-out failure mechanism;
Journal_Title :
Electronics Letters
DOI :