DocumentCode :
915715
Title :
Wear-out failure mechanism in fused-fibre couplers
Author :
Wilkinson, I.J.
Author_Institution :
BT Group Tech. Facilities, Birmingham, UK
Volume :
29
Issue :
12
fYear :
1993
fDate :
6/10/1993 12:00:00 AM
Firstpage :
1137
Lastpage :
1139
Abstract :
A wear-out failure mechanism found in singlemode fused-fibre couplers is proposed and evidence presented. Exposure to humidity causes a swelling of the epoxy supporting the taper which in turn applies strain. Defects on the surface of the taper grow under the combined effects of humidity and strain and can, eventually, cause a fracture.
Keywords :
environmental degradation; failure analysis; fracture; optical couplers; optical fibre testing; swelling; fracture; fused-fibre couplers; humidity exposure; swelling; taper surface defects; wear-out failure mechanism;