Title
Wear-out failure mechanism in fused-fibre couplers
Author
Wilkinson, I.J.
Author_Institution
BT Group Tech. Facilities, Birmingham, UK
Volume
29
Issue
12
fYear
1993
fDate
6/10/1993 12:00:00 AM
Firstpage
1137
Lastpage
1139
Abstract
A wear-out failure mechanism found in singlemode fused-fibre couplers is proposed and evidence presented. Exposure to humidity causes a swelling of the epoxy supporting the taper which in turn applies strain. Defects on the surface of the taper grow under the combined effects of humidity and strain and can, eventually, cause a fracture.
Keywords
environmental degradation; failure analysis; fracture; optical couplers; optical fibre testing; swelling; fracture; fused-fibre couplers; humidity exposure; swelling; taper surface defects; wear-out failure mechanism;