• DocumentCode
    917100
  • Title

    Form factor method yields thermal conductivity and radiated power of nitrogen arc

  • Author

    Pflanz, Herbert M. ; Horst, Diederik Th J Ter

  • Author_Institution
    Power Breaker Division, Allis-Chalmers, Boston, Mass.
  • Volume
    59
  • Issue
    4
  • fYear
    1971
  • fDate
    4/1/1971 12:00:00 AM
  • Firstpage
    601
  • Lastpage
    604
  • Abstract
    The form factor method for the determination of thermal conductivity is applied to experimental results obtained with a cascade arc in nitrogen. Experimental and theoretical thermal conductivities agree, even at temperatures above 10000°K if rather high radiation losses are taken into account. This result does not change significantly when reabsorption is considered by means of an absorption form factor and the total absorbed power.
  • Keywords
    Conductivity measurement; Current density; Electric variables measurement; Equations; Nitrogen; Shape measurement; Temperature measurement; Thermal conductivity; Thermal factors; Voltage;