• DocumentCode
    917900
  • Title

    Experimental study of factors affecting capacitance of high-voltage compressed-gas capacitors

  • Author

    Rungis, J. ; Brown, D.E.

  • Author_Institution
    Commonwealth Scientific and Industrial Research Organisation (CSIRO), National Measurement Laboratory, Division of Applied Physics, Sydney, Australia
  • Volume
    128
  • Issue
    4
  • fYear
    1981
  • fDate
    5/1/1981 12:00:00 AM
  • Firstpage
    273
  • Lastpage
    277
  • Abstract
    Various factors affecting the value and voltage dependence of the capacitance of high-voltage compressed-gas capacitors, used as high-voltage measurement standards, are considered. An experimental method for testing the mechanical stability of the electrodes is presented. Results of the comparison of a standard capacitor with other gas capacitors are presented, and it is concluded that a compressed-gas capacitor can be transported successfully if some precautions are taken.
  • Keywords
    capacitors; high-voltage techniques; measurement standards; voltage measurement; capacitance; electrode stability testing; high-voltage compressed-gas capacitors; high-voltage measurement standards;
  • fLanguage
    English
  • Journal_Title
    Physical Science, Measurement and Instrumentation, Management and Education - Reviews, IEE Proceedings A
  • Publisher
    iet
  • ISSN
    0143-702X
  • Type

    jour

  • DOI
    10.1049/ip-a-1.1981.0037
  • Filename
    4644994