DocumentCode :
918204
Title :
Influence of Sampling Period on a Class of Optimal Fault-Detection Performance
Author :
Zhang, Ping ; Ding, Steven X.
Author_Institution :
Inst. for Autom. Control & Complex Syst., Univ. of Duisburg-Essen, Duisburg
Volume :
54
Issue :
6
fYear :
2009
fDate :
6/1/2009 12:00:00 AM
Firstpage :
1396
Lastpage :
1402
Abstract :
In this note, the influence of sampling period on a widely accepted class of optimal fault-detection performance is studied. The background of this study is the important role played by the sampling period in embedded networked control systems. It is shown that the optimal H infin/H infin fault-detection performance index will become worse, if the sampling period is increased by an integer multiple. The main tool used for the analysis is the lifting technique, which bridges systems with different sampling periods.
Keywords :
Hinfin control; control engineering computing; optimal control; performance index; bridge system; embedded networked control system; optimal Hinfin/Hinfin fault-detection; sampling period; Automatic control; Bridges; Communication system control; Control systems; Fault detection; Fault diagnosis; Networked control systems; Performance analysis; Performance gain; Sampling methods; Embedded networked control systems; fault detection; lifting; optimal design; sampling period;
fLanguage :
English
Journal_Title :
Automatic Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9286
Type :
jour
DOI :
10.1109/TAC.2009.2015563
Filename :
4982653
Link To Document :
بازگشت