DocumentCode
918789
Title
A New Method for AC Machine Turn Insulation Diagnostic Based on High Frequency Resonances
Author
Perisse, Frédéric ; Werynski, Piotr ; Roger, Daniel
Author_Institution
LSEE Univ. d´´Artois, Bethune
Volume
14
Issue
5
fYear
2007
fDate
10/1/2007 12:00:00 AM
Firstpage
1308
Lastpage
1315
Abstract
The stator insulation breakdown is a major cause of ac machine failures. Ground insulation defaults are easily detected by classical systems based on leakage current measurements, however the turn-to-turn insulation degradations are more difficult to detect. For large machines, on-line methods, based on partial discharge detection and analysis, give good results but they cannot be used for low-voltage machines fed by adjustable speed drives (ASD). This paper presents a new monitoring system able to detect slight variations of high frequency resonances in the winding of a working machine fed by an industrial inverter. The new system works in association with statistical data on accelerated aging of the magnet wire used to build the machine.
Keywords
AC machines; electric breakdown; life testing; machine insulation; machine windings; maintenance engineering; AC machine failure; AC machine turn insulation diagnostic; accelerated aging; high frequency resonances; industrial inverter fed; life estimation; machine windings; magnet wire; monitoring system; power system monitoring; rotating machine insulation; statistical data; stator insulation breakdown; turn-to-turn insulation; AC machines; Current measurement; Electric breakdown; Insulation; Leak detection; Leakage current; Resonance; Resonant frequency; Stators; Variable speed drives;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/TDEI.2007.4339494
Filename
4339494
Link To Document