Abstract :
In order to match the electrical lengths of feedlines for a 2.5-km HF array, an extremely convenient and sensitive swept-frequency technique has been developed for feedline comparison. Implementation of this technique is described and its sensitivity to a 3-in difference in the lengths of two 4800-ft feedlines is experimentally demonstrated.