• DocumentCode
    919849
  • Title

    Adjustable AC capacitor for a single-phase induction motor

  • Author

    Muljadi, Eduard ; Zhao, Yifan ; Liu, Tian-Hua ; Lipo, Thomas A.

  • Author_Institution
    Nat. Renewable Energy Lab., Golden, CO, USA
  • Volume
    29
  • Issue
    3
  • fYear
    1993
  • Firstpage
    479
  • Lastpage
    485
  • Abstract
    The most common practice for starting a single-phase induction machine (SPIM) is to install a starting capacitor in series with the auxiliary winding. In some applications, two capacitors are used. One is used during the starting period to help create the starting torque. The other one is used during the running condition to improve efficiency. The possibility of using an electronic switch in parallel with the running capacitor, thereby providing the equivalent of a starting capacitor, is discussed. The capacitor is shorted during each cycle to vary the effective size of the AC capacitor. By using this method, only one capacitor is used for both the starting and running condition, and a starting performance similar to that of the conventional method using two capacitors can be obtained
  • Keywords
    induction motors; power capacitors; starting; torque; adjustable AC capacitor; auxiliary winding; electronic switch; single-phase induction motor; starting torque; Helium; Impedance; Induction machines; Induction motors; Industry Applications Society; Machine windings; Magnetic fields; Switched capacitor circuits; Switches; Torque;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/28.222415
  • Filename
    222415