Title :
Rapid detection and measurement of 3-phase reactive power, power and power factor
Author_Institution :
University of Birmingham, Department of Electronic & Electrical Engineering, Birmingham, UK
Abstract :
Established means for measuring or detecting reactive power, power or power factor have an inherent time delay, mainly because of the need for output filtering. This letter describes an arrangement employing sampling techniques, which, since no filtering is necessary, offers substantial advantages for control and monitoring applications.
Keywords :
power factor measurement; power measurement; reactive power; power factor; power measurement; sampling techniques; three phase reactive power;
Journal_Title :
Electronics Letters
DOI :
10.1049/el:19720417