  • Abstract
    The built-in test and embedded diagnostics for two subsystems of the M1A2 main battle tank, the commander´s independent thermal viewer and the hull/turret electronics unit, are examined. Each of these systems supports the requirements for elimination of special test equipment at the tank level and the use of standard army test equipment for test and repair at higher echelons of maintenance. The tradeoffs made during system requirements analysis and flow-down, which led to two unique design implementations, are described. The advantages and disadvantages of each approach are discussed.<>
  • Keywords
    automatic test equipment; built-in self test; electronic equipment testing; infrared detectors; maintenance engineering; military computing; military systems; M1A2 main battle tank; built-in test; diagnostics; digital logic equipment; embedded diagnostics; hull/turret electronics; maintenance; military computer; military systems; repair; standard army test equipment; thermal viewer; Assembly; Azimuth; Built-in self-test; Fault detection; Filters; Instruments; Power supplies; System testing; Test equipment; Wheels;