• DocumentCode
    920859
  • Title

    A time resolving data acquisition system for multiple high-resolution position sensitive detectors

  • Author

    Dimmler, D. Gerd

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • Volume
    35
  • Issue
    1
  • fYear
    1988
  • fDate
    2/1/1988 12:00:00 AM
  • Firstpage
    266
  • Lastpage
    271
  • Abstract
    An advanced time-resolving data collection system for use in neutron and X-ray spectrometry has been implemented and put into routine operation. The system collects data from high-resolution position-sensitive area detectors with a maximum cumulative rate of 106 events per second. The events are sorted, in real-time, into many time-slice arrays. A programmable timing control unit allows for a wide choice of time sequences and time-slice array sizes. The shortest dwell time on a slice can be below 1 ms, and the delay to switch between slices is zero.
  • Keywords
    data acquisition; physics computing; position sensitive particle detectors; 1 ms; X-ray spectrometry; dwell time; multiple high-resolution position sensitive detectors; neutron spectrometry; programmable timing control unit; time resolving data acquisition system; time sequences; time-slice array sizes; Data acquisition; Event detection; Foot; Graphics; Neutrons; Position sensitive particle detectors; Sensor arrays; Spectroscopy; Switches; Timing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.12721
  • Filename