• DocumentCode
    921985
  • Title

    Tests of the SGS D779 based readout electronics for the SLD limited streamer tube strips

  • Author

    Beconcini, F. ; Bilei, G.M. ; Castaldi, R. ; Cazzola, U. ; Dell´Orso, R. ; Verdini, P.G.

  • Author_Institution
    Dipartimento di Fisica dell´´Univ., Istituto Nazionale di Fisica Nucl., Pisa, Italy
  • Volume
    35
  • Issue
    1
  • fYear
    1988
  • fDate
    2/1/1988 12:00:00 AM
  • Firstpage
    311
  • Lastpage
    315
  • Abstract
    A study has been made of the properties of the SGS D779-based readout electronics for limited streamer tubes, both with pulses from a pulse generator and with strip pulses from the actual chambers to be used in the SLD detector. To accommodate the special requirements of the SLD detector, a hybrid circuit has been developed and tested that is capable of operating with pulses from the strips of tubes operated below the limited-streamer-node voltages.
  • Keywords
    hybrid integrated circuits; pulse circuits; streamer chambers; SGS D779 based readout electronics; SLD limited streamer tube strips; hybrid circuit; limited-streamer-node voltages; Circuit testing; Detectors; Electron tubes; Electronic equipment testing; Pulse circuits; Pulse generation; Readout electronics; Strips; Superluminescent diodes; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.12732
  • Filename
    12732