• DocumentCode
    922904
  • Title

    Wall Voltage and Priming Effect Due to Auxiliary Electrode in AC PDP With Auxiliary Electrode

  • Author

    Cho, Kwan Hyun ; Lee, Sung-Min ; Choi, Kyung Cheol

  • Author_Institution
    Korea Adv. Inst. of Sci. & Technol., Daejeon
  • Volume
    35
  • Issue
    5
  • fYear
    2007
  • Firstpage
    1567
  • Lastpage
    1573
  • Abstract
    Variation of wall voltage and priming effect due to an auxiliary electrode are investigated with the aim of attaining a better understanding of the discharge phenomenon in an ac plasma display panel with an auxiliary electrode. A periodic positive pulse, which is applied to the auxiliary electrode during afterglow, reduced wall charges accumulated on the auxiliary and sustain electrodes so that discharge current decreased with an increase of auxiliary-pulse voltage. In addition, the auxiliary pulse influenced on the priming particles so that the optical output was not changed as much as the reduced current and sustain voltage was lowered. Based on these results, modified auxiliary-pulse waveforms, i.e., dual auxiliary pulses, were applied to the auxiliary electrode to utilize more priming particles to improve luminous efficacy. The proposed auxiliary waveforms improved IR efficiency by 10%-15% as compared to that obtained with a single auxiliary pulse.
  • Keywords
    electrodes; plasma displays; AC PDP; ac plasma display panel; auxiliary electrode; discharge phenomenon; priming effect; wall voltage; Digital TV; Electrodes; Energy consumption; HDTV; Measurement units; Optical pulses; Plasma displays; Power dissipation; Pulse measurements; Voltage; Auxiliary electrode; detecting pulse; plasma display panel (PDP); priming effect; wall voltage;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.2007.905207
  • Filename
    4343144