DocumentCode :
923920
Title :
Transient Response of a Narrow-Band Automatic Frequency-Control System
Author :
Miller, Theodore
Author_Institution :
Westinghouse Research Laboratories, Westinghouse Electric Corp., East Pittsburgh, Pa.
Volume :
39
Issue :
11
fYear :
1951
Firstpage :
1433
Lastpage :
1436
Abstract :
A method of analyzing the response of automatic frequency-control systems, operating in conjunction with a narrow band-pass filter, is presented in this paper. A time-lag, equivalent to the reciprocal of the bandwidth, is assigned to the filter. Circuit parameters are established for operation near the critically damped response condition. The equations of the system are derived with the aid of the Laplace transform. The method of residues is used to evaluate the transient response to a step-input frequency disturbance.
Keywords :
Automatic frequency control; Band pass filters; Circuits; Delay; Laplace equations; Local oscillators; Narrowband; Proportional control; Transient response; Voltage;
fLanguage :
English
Journal_Title :
Proceedings of the IRE
Publisher :
ieee
ISSN :
0096-8390
Type :
jour
DOI :
10.1109/JRPROC.1951.273608
Filename :
4050566
Link To Document :
بازگشت