• DocumentCode
    925237
  • Title

    Electrical isolation of a 0-section in a transfinite electrical network

  • Author

    Zemanian, A.H.

  • Author_Institution
    Dept. of Electr. Eng., State Univ. of New York, Stony Brook, NY, USA
  • Volume
    40
  • Issue
    4
  • fYear
    1993
  • fDate
    4/1/1993 12:00:00 AM
  • Firstpage
    233
  • Lastpage
    238
  • Abstract
    A 0-section of a transfinite electrical network is a maximal subnetwork that is connected in the usual sense, i.e., there is a finite path between every two nodes. Conditions are established ensuring that a 0-section M is electrically isolated from all other 0-sections. This means that a source in M never induces currents beyond the infinite extremities of M. The conditions are on both the graph and the element values of M
  • Keywords
    graph theory; network analysis; network topology; electrical isolation; element values; finite path; graph values; infinite extremities; maximal subnetwork; transfinite electrical network; Electric resistance; Extremities; Graph theory; H infinity control; Intelligent networks; Visualization; Voltage;
  • fLanguage
    English
  • Journal_Title
    Circuits and Systems I: Fundamental Theory and Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1057-7122
  • Type

    jour

  • DOI
    10.1109/81.224295
  • Filename