DocumentCode :
925876
Title :
Noninvasive vacuum integrity tests on fast warm-up traveling-wave tubes
Author :
Dallos, A. ; Carignan, R.G.
Author_Institution :
Raytheon Co., Waltham, MA, USA
Volume :
36
Issue :
4
fYear :
1989
fDate :
4/1/1989 12:00:00 AM
Firstpage :
827
Lastpage :
828
Abstract :
A method of tube vacuum monitoring that uses the tube´s existing internal electrodes as an ion gauge is discussed. This method has been refined using present-day instrumentation and has proved to be a precise, simple, and fast method of tube vacuum measurement. The method is noninvasive due to operation of the cathode at low temperature, which minimizes pumping or outgassing. Because of the low current levels to be measured, anode insulator leakage must be low, and the leads must be properly shielded to minimize charging effects. A description of the method, instrumentation used, limitations and data showing results over a period of 600 days are presented
Keywords :
electron tube testing; monitoring; travelling-wave-tubes; vacuum measurement; TWT; fast warm-up; internal electrodes; ion gauge; microwave tubes; noninvasive method; shielded leads; traveling-wave tubes; tube vacuum monitoring; vacuum integrity tests; vacuum measurement; Anodes; Cathodes; Current measurement; Electrodes; Electron tubes; Instruments; Insulation; Monitoring; Temperature; Testing;
fLanguage :
English
Journal_Title :
Electron Devices, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9383
Type :
jour
DOI :
10.1109/16.22494
Filename :
22494
Link To Document :
بازگشت