Title : 
A Dual Six-Port Automatic Network Analyzer
         
        
            Author : 
Cronson, Harry M. ; Susman, Leon
         
        
        
        
        
            fDate : 
4/1/1981 12:00:00 AM
         
        
        
        
            Abstract : 
A 2- to 18-GHz dual six-port automatic network analyzer using diode power detectors is described. An analysis of the calibration technique is discussed in detail. Measurement accuracies of better than 0.1-dB up to 40-dB insertion loss from 2 to 7 GHz are reported. Possible causes of the errors observed at higher frequencies are given.
         
        