• DocumentCode
    927084
  • Title

    The Determination of Impedance with a Double-Slug Transformer

  • Author

    Ellenwood, R.C. ; Hurlburt, E.H.

  • Author_Institution
    U. S. Department of Commerce, National Bureau of Standards, Washington 25, D.C.
  • Volume
    40
  • Issue
    12
  • fYear
    1952
  • Firstpage
    1690
  • Lastpage
    1693
  • Abstract
    Formulas are derived and techniques given by means of which impedance measurements can be made by the use of a double-slug transformer. The required parameters are the length, spacing, position, and "effective" dielectric constant of the slugs, and the wavelength. A means for the experimental determination of the "effective" dielectric constant is described. The only quantitative measurements required are of length. A qualitative recognition of the electrically matched condition is needed.
  • Keywords
    Coaxial components; Conductors; Dielectric constant; Dielectric measurements; Frequency; Impedance matching; Impedance measurement; Instruments; Length measurement; Transmission lines;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1952.274151
  • Filename
    4050891