• DocumentCode
    927873
  • Title

    Pulse discharge control and machine protection for a multi-discharge compulsator

  • Author

    Thelen, R.F.

  • Author_Institution
    Centre for Electromech., Texas Univ., Austin, TX, USA
  • Volume
    25
  • Issue
    1
  • fYear
    1989
  • fDate
    1/1/1989 12:00:00 AM
  • Firstpage
    546
  • Lastpage
    551
  • Abstract
    A compensated pulse alternator (compulsator) to power railgun research experiment has been designed and built. The author presents the control design considerations and strategies used in the control of proper output pulses and the detection and clearing of faults. Since the compulsator is designed for limited pulse duty, particular emphasis is placed on reliability and redundancy in the fault-control system to avert potentially massive generator damage. The circuit has provided reliable performance through the system testing. Other circuits, designed to protect the compulsator from short-circuit fault damage, have also been successfully implemented
  • Keywords
    alternators; electromagnetic launchers; programmable controllers; short-circuit currents; compensated pulse alternator; control design considerations; fault cleaning; fault detection; fault-control system; generator damage; limited pulse duty; machine protection; multi-discharge compulsator; output pulse control; power railgun; pulse discharge control; redundancy; reliability; short-circuit fault damage; system testing; Alternators; Circuit faults; Control design; Electrical fault detection; Fault detection; Power system reliability; Protection; Pulse generation; Railguns; Redundancy;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.22598
  • Filename
    22598