• DocumentCode
    928981
  • Title

    A Frequency Stabilization System for Microwave Gas Dielectric Measurements

  • Author

    Gabriel, William F.

  • Author_Institution
    Antenna Research Branch, Radio Division I, Naval Research Laboratory, Washington 25, D.C.
  • Volume
    40
  • Issue
    8
  • fYear
    1952
  • Firstpage
    940
  • Lastpage
    945
  • Abstract
    A system is described for measunng the dielectric constant of a gas at uhf by observing the shift in resonant frequency of a cavity when filled with the gas to be measured. To do this, a klystron oscillator is stabilized with great precision on the cavity resonant frequency by means of a double-loop servo system. One loop is of the Pound type, which is effective against almost all frequency fluctuations. The other is a motor-type control which further reduces any small, steady, frequency error left by the electronic Pound loop. The two combine to give control that is better than one part in 108, and this is sufficient to obtain values of (no-1), where no is the index of refraction, accurate to three places.
  • Keywords
    Dielectric constant; Dielectric measurements; Error correction; Fluctuations; Frequency measurement; Klystrons; Microwave oscillators; Resonant frequency; Servomechanisms; UHF measurements;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IRE
  • Publisher
    ieee
  • ISSN
    0096-8390
  • Type

    jour

  • DOI
    10.1109/JRPROC.1952.274105
  • Filename
    4051083