• DocumentCode
    931848
  • Title

    Ceramic-based multisite electrode arrays for chronic single-neuron recording

  • Author

    Moxon, Karen A. ; Leiser, Steve C. ; Gerhardt, Greg A. ; Barbee, Kenneth A. ; Chapin, John K.

  • Author_Institution
    Sch. of Biomed. Eng. Sci. & Health Syst., Drexel Univ., Philadelphia, PA, USA
  • Volume
    51
  • Issue
    4
  • fYear
    2004
  • fDate
    4/1/2004 12:00:00 AM
  • Firstpage
    647
  • Lastpage
    656
  • Abstract
    A method is described for the manufacture of a microelectrode array for chronic, multichannel, single neuron recording. The ceramic-based, multisite electrode array has four recording sites patterned onto a ceramic shaft the size of a single typical microwire electrode. The sites and connecting wires are applied to the ceramic substrate using a reverse photolithographic procedure. Recording sites (22×80 μm) are separated by 200 μm along the shaft. A layer of alumina insulation is applied over the whole array (exclusive of recording sites) by ion-beam assisted deposition. These arrays were capable of recording single neuron activity from each of their recording sites for at least three weeks during chronic implantation in the somatosensory cortex of rats, and several sites had recordings that lasted for more than 8 weeks. The vertical arrangement of the recording sites on these electrodes is ideal for simultaneously recording across the different layers of brain areas such as the cerebral cortex and hippocampus in chronic preparations.
  • Keywords
    biological techniques; biomedical electrodes; brain; ceramics; ion beam assisted deposition; microelectrodes; neurophysiology; photolithography; alumina insulation; brain; ceramic-based multisite electrode arrays; cerebral cortex; chronic implantation; chronic single-neuron recording; hippocampus; ion-beam assisted deposition; microelectrode array; microwire electrode; photolithography; somatosensory cortex; Ceramics; Electrodes; Insulation; Joining processes; Manufacturing; Microelectrodes; Neurons; Rats; Shafts; Wires; Action Potentials; Animals; Ceramics; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Male; Microelectrodes; Monitoring, Ambulatory; Nerve Net; Neurons; Rats; Rats, Long-Evans; Reproducibility of Results; Sensitivity and Specificity; Somatosensory Cortex;
  • fLanguage
    English
  • Journal_Title
    Biomedical Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9294
  • Type

    jour

  • DOI
    10.1109/TBME.2003.821037
  • Filename
    1275580