DocumentCode
932590
Title
Measurements of Detector Output Spectra by Correlation Methods
Author
Weinberg, Louis ; Kraft, L.G.
Author_Institution
Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts. At present with Hughes Research and Development Laboratories, Culver City, California
Volume
41
Issue
9
fYear
1953
Firstpage
1157
Lastpage
1166
Abstract
The correlation technique is applied experimentally to determine the power density spectra of the output of two non-linear devices, the linear and square-law rectifiers. Curves of the input and output autocorrelation functions obtained experimentally for inputs of filtered noise with and without a sine wave are compared with the theoretically calculated curves, and thus an experimental check on some known theoretical results is obtained.
Keywords
Autocorrelation; Circuit noise; Correlation; Density measurement; Detectors; Laboratories; Mathematical analysis; Nonlinear circuits; Rectifiers; Writing;