Title :
Study of the 87Rb maser with both ends pumping
Author :
Jinquan, Deng ; Xiwen, Zhu ; Yuanhai, Xiang
Author_Institution :
Wuhan Inst. of Phys., Acad. of Sci., Wuhan, China
fDate :
6/1/1993 12:00:00 AM
Abstract :
Experiments on the 87Rb maser with both ends pumping showed variations of the maximum output power versus cell temperature. The largest output power was 2.0×10-10 W, and a preliminary measurement gave an improved short-term frequency stability. The results of the numerical calculations based on the density matrix formalism agreed qualitatively with the experiments
Keywords :
atomic beams; frequency measurement; masers; measurement standards; optical pumping; rubidium; 2.0*10-10 W; 87Rb maser; density matrix formalism; frequency standard; numerical calculations; short-term frequency stability; Electron tubes; Frequency measurement; Lamps; Masers; Packaging; Physics; Power generation; Stability; Temperature distribution; Temperature measurement;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on