• DocumentCode
    934520
  • Title

    Factors Affecting Hamamatsu H8500 Flat Panel PMT Calibration for Gamma Ray Imaging

  • Author

    Pani, Roberto ; Pellegrini, Rosanna ; Cinti, Maria Nerina ; Trotta, Carlo ; Trotta, Gianfranco ; Scafè, Raffaele ; D´Addio, L. ; Iurlaro, Giorgia ; Montani, Livia ; Bennati, Paolo ; Ridolfi, Stefano ; Cusanno, Francesco ; Garibaldi, Franco

  • Author_Institution
    Univ. of Rome La Sapienza, Rome
  • Volume
    54
  • Issue
    3
  • fYear
    2007
  • fDate
    6/1/2007 12:00:00 AM
  • Firstpage
    438
  • Lastpage
    443
  • Abstract
    The Hamamatsu H8500 Flat Panel PMT is the latest technological advancement in gamma ray imaging. Its compact size makes it attractive for medical imaging applications. To study and compare image performance a Flat Panel PMT, representing the present production, was coupled to CsI(Tl) and Nal(Tl) scintillation arrays with 3 mm and 1.8 mm pixel size respectively and connected to a multi-anode electronic readout. Furthermore, a pulsed blue LED coupled to an optical liber was utilized to scan the tube with different light distributions. This study investigated how PMT anode gain uniformity response, scintillation light distribution and intensity influence the spatial resolution, the position linearity and the image noise. Each crystal in the scintillation array produces a different charge distribution, which depends on the match between the anode size and the scintillation array lattice. The Nal(Tl) array demonstrated to fit both PMT characteristics and dynamic range of electronic read out, due to the charge distribution adequate to the anode size. For CsI(Tl) crystal, the pulse height calibration resulted more critical, due to the narrow light distribution. In conclusion, the use of Flat Panel tube with selected anode gain uniformity could represent the cheapest and easiest solution to obtain the best image quality, in particular for scintillator array with smaller pixel size.
  • Keywords
    anodes; caesium compounds; calibration; diagnostic radiography; flat panel displays; light emitting diodes; readout electronics; scintillation; sodium compounds; CsI - Binary; CsI(Tl) scintillation arrays; Hamamatsu H8500 flat panel PMT calibration; NaI - Binary; Nal(Tl) scintillation arrays; PMT anode gain; charge distribution; gamma ray imaging; image noise; medical imaging; multianode electronic readout; position linearity; pulsed blue LED; Anodes; Biomedical imaging; Calibration; Light emitting diodes; Nuclear imaging; Optical coupling; Optical noise; Optical pulses; Pixel; Production; Nuclear imaging; photomultipliers; scintillation detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2007.897033
  • Filename
    4237432