  • Abstract
    A description is given of a ring imaging Cherenkov (RICH) counter that uses a multiwire proportional chamber with cathode-pad readout as an ultraviolet photon detector. The detector has 10800 pads, each connected to a charge-sensitive amplifier, within an area of 58 cm*95 cm. The detector offers high-data-rate capability, a chamber sensitive time of less than 250 ns, 1-mm spatial resolution, and a multibit capability of about 50 photons/event.<>
  • Keywords
    Cherenkov counters; position sensitive particle detectors; proportional counters; Fermilab experiment 665; cathode-pad readout; chamber sensitive time; charge-sensitive amplifier; high-data-rate capability; multibit capability; multiwire proportional chamber; ring imaging Cherenkov detector; spatial resolution; ultraviolet photon detector; Absorption; Anodes; Cathodes; Computed tomography; Counting circuits; Detectors; Event detection; Jitter; Mirrors; Spatial resolution;