• DocumentCode
    936488
  • Title

    Overhead distribution lines¿some reflections on design

  • Author

    Orawski, G. ; Bradbury, J. ; Vanner, M.J.

  • Author_Institution
    Balfour Beatty Power Construction Ltd., Power Transmission Division, Thornton Heath, UK
  • Volume
    133
  • Issue
    7
  • fYear
    1986
  • fDate
    11/1/1986 12:00:00 AM
  • Firstpage
    409
  • Lastpage
    424
  • Abstract
    While existing regulations regarding the design of overhead lines have served well the electricity supply industry, recent happenings, when many networks suffered damage in Europe, have highlighted the need for a critical review of design practices. It is argued that, provided some statistical data on meteorological phenomena are available, attempts could be made to design overhead lines to suit subsequent performance requirements. The ultimate load design concept is favoured, in which an anticipated load with a quantified probability of occurrence is compared with the strength of a component having a selected probability of being achieved. Besides, it is suggested that, by the use of suitable coefficients, a preconceived coordination of strengths of the components can be obtained. Due to electrical constraints, there is a limit on conductor sizes, beyond which there is no measurable improvement in electrical performance. There is obviously an economic impact which must be appreciated. For a rapid assessment of a suitable voltage and conductor size the technique of kVA-km is a handy design tool. Analysis of many km-years of performance of overhead lines in general has proved useful in defining guidelines for insulation selection. A similar exercise on the lightning performance of distribution lines seems to indicate the beneficial influence of earthwires, although some simplified theoretical considerations would have led to a somewhat different conclusion. Notwithstanding the many efforts by various suppliers to provide alternative types of materials for the supports, these are normally made of either wood or steel. To satisfy specific requirements they can take many shapes to obtain a variety of conductor configurations. Foundations designed for overturning are most commonly used for distribution lines, although the design techniques are seldom taught to students. Designing foundations for overhead lines should remain a challenge to civil engineers.
  • Keywords
    load (electric); overhead line conductors; power overhead lines; supports; conductor configurations; conductor sizes; earth wires; electrical performance; foundation design; lightning performance; load design; meteorological phenomena; overhead distribution lines; overhead line conductors; support;
  • fLanguage
    English
  • Journal_Title
    Generation, Transmission and Distribution, IEE Proceedings C
  • Publisher
    iet
  • ISSN
    0143-7046
  • Type

    jour

  • DOI
    10.1049/ip-c:19860061
  • Filename
    4646926