• DocumentCode
    938108
  • Title

    A Precision Attenuation Standard for X Band

  • Author

    Clark, R.F. ; Dean, B.J.

  • Author_Institution
    Radio and Electrical Engineering Division, National Research Council of Canada, Ottawa, Ontario, Canada.
  • Issue
    3
  • fYear
    1962
  • Firstpage
    291
  • Lastpage
    293
  • Abstract
    The X-band attenuation is compared with that of a calibrated 30-Mc reference attenuator by means of a linear superheterodyne detector. Estimated accuracy is ±(0.010 db+0.005 db/10 db) for a dynamic range of 40 db. Frequency control of the signal and local oscillator klystrons, stabilization of the signal power level, and use of a stable IF amplifier have resulted in a drift for the standard of less than ±0.005 db per five-minute interval.
  • Keywords
    Attenuation; Attenuators; Calibration; Detectors; Diodes; Frequency; Instruments; Klystrons; Local oscillators; Voltage;
  • fLanguage
    English
  • Journal_Title
    Instrumentation, IRE Transactions on
  • Publisher
    ieee
  • ISSN
    0096-2260
  • Type

    jour

  • DOI
    10.1109/IRE-I.1962.5006647
  • Filename
    5006647