DocumentCode :
939956
Title :
A Study of Parylene C Polymer Deposition Inside Microscale Gaps
Author :
Ramachandran, Anup ; Junk, Michael ; Koch, Klaus Peter ; Hoffmann, Klaus-Peter
Author_Institution :
Univ. of Konstanz, Konstanz
Volume :
30
Issue :
4
fYear :
2007
Firstpage :
712
Lastpage :
724
Abstract :
Parylene C is a biocompatible polymer that has been investigated as an encapsulation material for implantable microsystems. Since parylene C is deposited directly on the substrate from the vapor phase it can conform to a wide range of geometries. However, the thickness of the deposited layer tends to decrease in microscale gaps, which might lead to an insulation failure. To ensure more robustness of the coating, the changes in parylene C coating thickness have been investigated experimentally using simple gaps of known dimensions. In an attempt to better understand these experimental findings, two theoretical models have been developed. The first one, which is based on a diffusion approximation, is able to reproduce and extrapolate the experimental results, leading to a useful design rule for practical applications involving parylene C coating. As an example, we present the substrate design of a flexible sieve electrode for a peripheral nerve interface. The second model aims at an appropriate microscopic description of the coating process in terms of kinetic theory of gases.
Keywords :
electrochemical electrodes; electrodeposition; polymer films; vapour deposited coatings; biocompatible polymer; encapsulation material; flexible sieve electrode; implantable microsystems; kinetic theory; microscale gaps; microscopic description; parylene coating thickness; parylene polymer deposition; peripheral nerve interface; Deposition; Parylene C; implant; multiplexer; neuroprosthesis; polyimide; sieve electrode;
fLanguage :
English
Journal_Title :
Advanced Packaging, IEEE Transactions on
Publisher :
ieee
ISSN :
1521-3323
Type :
jour
DOI :
10.1109/TADVP.2007.901662
Filename :
4358042
Link To Document :