Abstract :
This paper describes the design of two magnetic concentrators that can be used to intensify the magnetic field in the active region of magnetic sensors, such as Hall sensors. The literature provides many examples of magnetic amplification, but magnetic gains never exceed 100 typically (Drljaca et al. 2001, Drljaca et al. 2002). We demonstrate that a larger magnetic field amplification (~1000 and even higher) can be achieved. Magnetic field amplification can even exceed the theoretical value fixed by the relative permeability of the material. Thus, the effective sensitivity of Hall sensors can be improved by at least three orders of magnitude by implementing them inside an especially tailored magnetic concentrator; noise-equivalent magnetic induction spectral density (National Electronics Manufacturing Initiative spectral density) down to 10 pT/radic(Hz) should be reached, using a good conditioning electronic
Keywords :
Hall effect transducers; magnetic fields; magnetic sensors; Hall sensors; magnetic concentrators; magnetic field amplification; magnetic induction spectral density; magnetic sensors; magnetometers; Magnetic field measurement; Magnetic fields; Magnetic flux; Magnetic noise; Magnetic sensors; Magnetosphere; Permeability; Saturation magnetization; Sensor phenomena and characterization; Signal to noise ratio; Hall sensors; magnetic amplification; magnetometers;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2006.874031
Filename :
1634424
Link To Document :
بازگشت