  • Abstract
    A configuration for realising a 2nd-order bandpass filter based on the single-pole roll-off characteristics of the operational amplifier with a single grounded external capacitor is presented. The filter has low sensitivity to all the circuit parameters. Experimental results verify its suitability in high-frequency applications with moderately high selectivity. Independent control of centre frequency, frequency selectivity and midband gain is possible.
  • Keywords
    active filters; band-pass filters; active filters; low sensitivity; moderately high selectivity; operational amplifier; second order bandpass filter; single grounded external capacitor;