• DocumentCode
    944085
  • Title

    Measurements of ramp-rate limitation of cable-in-conduit conductors

  • Author

    Takayasu, M. ; Ferri, M.A. ; Gung, C.Y. ; Painter, T.A. ; Steeves, M.M. ; Minervini, J.V.

  • Author_Institution
    Plasma Fusion Center, MIT, Cambridge, MA, USA
  • Volume
    3
  • Issue
    1
  • fYear
    1993
  • fDate
    3/1/1993 12:00:00 AM
  • Firstpage
    456
  • Lastpage
    459
  • Abstract
    The ramp-rate limitation found in the US-demonstration poloidal coil (US-DPC) test was studied in a laboratory scale experiment. The ramp-rate sensitivity has been identified on a 27-strand cable-in-conduit conductor at a background ramped field to 9.5 T with various ramp rates of 0.5 T/s to 2 T/s, simulating the US-DPC test conditions. A model assuming the existence of periodic disturbances is proposed in which the disturbance frequency is directly proportional to the ramp rate of the square of field. A semi-empirical formula was developed which fits the ramp-rate limitation data of both the US-DPC large coil and the 27-strand cable. The ramp-rate limitation does not occur for currents below the conventional limiting current.<>
  • Keywords
    fusion reactor materials; superconducting magnets; 27-strand cable-in-conduit conductor; 9.5 T; US-DPC; US-demonstration poloidal coil; background ramped field; disturbance frequency; limiting current; periodic disturbances; ramp-rate limitation; ramp-rate sensitivity; Coils; Communication cables; Conductors; Laboratories; Magnetic flux; Performance evaluation; Plasma measurements; Power cables; Solids; Testing;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/77.233742
  • Filename
    233742