DocumentCode
945659
Title
Nondestructive Gyrotron Cold-Cavity Q Measurements
Author
Woskoboinikow, Paul P. ; Mulligan, William J.
Volume
35
Issue
2
fYear
1987
fDate
2/1/1987 12:00:00 AM
Firstpage
96
Lastpage
100
Abstract
A novel method for cold testing a gyrotron resonator to determine its total Q is presented. Probing radiation is coupled into the resonator through its radiation pattern. A sensitive heterodyne receiver is used in the far field to detect the reradiated cavity resonances. Good agreement between measurement and calculated total Q is found for several 140-GHz gyrotron resonators in the TE031, TEsub 032/, TE231, and TE611 modes.
Keywords
Frequency; Gyrotrons; Millimeter wave measurements; Millimeter wave technology; Plasma applications; Plasma diagnostics; Q factor; Q measurement; Resonance; Testing;
fLanguage
English
Journal_Title
Microwave Theory and Techniques, IEEE Transactions on
Publisher
ieee
ISSN
0018-9480
Type
jour
DOI
10.1109/TMTT.1987.1133609
Filename
1133609
Link To Document